3com CS/2500 User Manual

Page of 116
Cabling the Server to the Network
2-5
All ports are set to terminal (
SETDefault -TERM DeVice = 
Terminal
). 
BAud is set to AutoBaud (
SETDefault -TERM BAud = AutoBaud
). 
PARIty is set to None (
SETDefault -TERM PARIty = None
). 
If your network hardware does not match these defaults, you must 
reconfigure the software. Refer to Chapter 20, “TERM Service 
Parameters,” in the Multiprotocol Communications Server Reference 
Guide
.
Devices connect to the server for communications purposes through the 
ten serial ports. An RBCS or TFTP server from which the 
communications server boots over the network connects as part of the 
network, through the Ethernet AUI connector.
Attaching RS-232 and RS-422 Serial Cables
Attach the serial cable to the server by inserting the connector into one 
of the back panel serial ports labeled J0 through J9. Using a small 
slotted screwdriver, tighten the screws on both sides of the connector.
Cabling a Console
The default console port is J0, and the default console port data rate is 
9600 bps. Because port J0 is the default, you must attach the console to 
this port the first time you configure your server. Table 2-1 lists the 
default settings for the server’s default console port, J0. Your terminal 
must match these settings. 
Table 2-1   Console Port Configuration
Parameter
Setting
Baud rate
9600
Number of data bits
8
DTR
Ignored
Duplex
Full
Echo
Off
Flow control
XON/XOFF
Parity
None
Stop bits
1
CS2500BookFile : Installation  Page 5  Thursday, December 11, 1997  10:44 AM