B&B Electronics ESP904 User Manual

Page of 39
 
 
Installing Virtual COM Port 
Manual Documentation Number: ESP904-0504 
Chapter 6 
39 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
 
 
Figure 26. The Windows Logo Testing Window 
This XP feature simply indicates that these drivers have not yet undergone 
the Microsoft testing procedures required to use the Windows XP Logo on 
the packaging. Driver compatibility is not affected. 
Step 4: Select 
Continue Anyway
 to proceed with the installation. 
The Protocol TCP/UDP, IP Address, and Port Number will mirror the 
settings of the selected serial server. 
Step 5: After setting all four ESP Serial Ports as virtual COM ports, select 
Cancel
 on the 
Found Server
 form. 
N
N
o
o
t
t
e
e
:
:
 
 
 
PCs may have hardware COM ports and devices such as Modems, IR ports or 
USB based COM ports that are not currently connected Try selecting a COM 
number above COM4 if problems occur. 
The default 
Flow Control
 setting is 
None
. RTS/CTS can be selected if used 
by the application program and serial hardware. The ESP Server must be set 
to match. 
 Installing 
Virtual 
COM 
Port 
40 
Chapter 6 
Manual Documentation Number: ESP904-0504 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
 
 
Matching the ESP904 and Virtual COM Port Settings 
The settings of the virtual COM ports in the Device Manager and the ESP904 
Configuration menu must match. If the settings do not match, the virtual 
COM ports will not work. If these settings are changed in the Device 
Manager, it will only affect the operation of the virtual COM port. It will not 
change the settings stored in the ESP904. Use the ESP Manager to change 
the ESP904 Server settings. 
Step 1:    Use Device Manager to 
View New Ports
 
 Confirm the virtual COM ports in the Device Manager.  
Step 2:   Double-click 
Ports
 to view the list of COM port numbers. 
The installed Virtual COM port will be displayed as 
VLINX ESP (COM #)
 
Figure 27. The Device Manager Window 
Step 3: In the Device Manager select a 
VLINX ESP COM#.
 Double-click it to 
bring up the 
Properties
 window.