After connection, the LAN is transparent to the program and serial device. 
Applications are able to work just as if the serial device is connected directly 
to a physical COM port on the computer. The virtual COM port software 
converts the application’s data into IP packets, sends it across the network to 
the ESP904, which converts the IP packet back to serial data and sends the 
data out a serial port located on the ESP904. 
To use this mode, the ESP904 must be set to either TCP/server or 
UDP/server with a designated communication port number. The virtual COM 
driver is the TCP or UDP client.  
Paired Mode 
Paired Mode 
is also called serial tunneling. In this mode any two serial 
devices that can communicate with a serial link will be able to communicate 
using two ESP904s and the LAN. 
Two ESP904s are connected to a network, one configured as a TCP or UDP 
client and the other as a TCP/UDP server. When setting up the server the 
remote IP address section must contain the address of the client. This will 
allow the client’s IP address to pass the IP address-filtering feature of the 
server. Conversely, the Remote IP address of the client must contain the 
server’s IP address. Both communication port numbers must be the same.  
Heart Beat 
The 
Heart Beat
 protocol connection provides a reliable communications 
connection in 
Virtual COM Port Mode
 or with
 
Paired Connection Mode
This feature restores the connection if communications are temporarily lost at 
either end due to loss of power or Ethernet connection. 
Without this feature a device that loses a connection and stops 
communicating would not be able to reconnect without human intervention. 
A TCP data connection can be lost when there is a power failure or 
temporary loss of an Ethernet connection on either the client or server. If a 
loss occurs the Heart Beat feature will try to reconnect the TCP data 
connection every five seconds until communications is established again. The 
Heart Beat feature is available for use in 
Virtual COM Port
 
Mode
 and 
Paired 
Connection
 mode. This is not available when using a UDP application.  
 Introduction 
Chapter 1 
Manual Documentation Number: ESP904-0504 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
 
ESP904 Quick Start Guide 
 
Hardware Setup  
Required hardware:  
  A PC operating on an Ethernet LAN. 
  A serial device with a RS-232 interface. 
  Network and serial cables, as required. 
Step 1:   Connect the ESP904 to the network using a standard network cable 
Step 2:   Connect the ESP904 to the RS-232 serial device.  
N
N
o
o
t
t
e
e
:
:
 
 
 
 
 
 
If the serial device is configured as a DCE use a straight-through serial cable. If 
the serial device is configured as a DTE use a crossover (null modem) cable. 
 
Figure 2. Quick Start Hardware Setup 
Software Installation 
Using the CD included with the ESP904, install the 
VLINX ESP Manager
 
software on the configuring computer.