Belkin LH R User Manual

Page of 126
Appendix B
Specifications
102
Weight and Dimensions
NOTE
A fully-loaded NetServer can weigh up to 176 pounds. Follow
local regulations, and use one person for every 40 pounds of
NetServer weight when lifting it.
HP NetServer LH 4
Height
494.8 mm (19.5 in)
Width
350.5 mm (13.8 in)
Depth
724.2 mm (28.5 in)
Weight
35 - 50 kg (77 - 110 lb)
HP NetServer LH 4r
Height
354.7 mm (14 in)
Width
482.6 mm (19 in)
Depth
749.2 mm (29.5 in)
Weight
35 - 50 kg (77 - 110 lb)
Power Supplies
Power Supply Specifications: Single power supply
Power supply type
Input voltages:
Nominal:
Range:
Auto-Ranging
100 to 127 VAC ~ 5 A at 50/60 Hz
200 to 240 VAC ~ 2.5 A at 50/60 Hz
90 to 132 VAC at 47 - 63 Hz
180 to 264 VAC at 47 - 63 Hz
Power supply:
550 W continuous
Worst Case Scenario for System
Voltage
Volt/Amps
Amps
Watts
100
1170
11.7
1140
120
1160
9.7
1130
200
1130
5.9
1100
230
1120
4.9
1100