Installing the NetServer in an HP Rack System/E or Rack System/U
49
Installing Rack Nuts
Rack nuts are installed on the front columns to secure the bezel latch and hinge.
Use the rack template to locate the mounting holes (see Figure 8-3).
Rack nuts are installed on the rear columns to secure the z-bracket, which is
secured to the NetServer. Use the rack template to locate the mounting holes.
1. 
 
Install the bezel latch rack nuts on the right front column (holes 11 and
15  counted up from the base line).
2. 
 
Install the bezel hinge rack nuts on the left front column (holes 6 and 19 
counted up from the base line).
3. 
 
Install the z-bracket rack nuts on the right rear column  (holes 9 and 13 
counted up from the base line).
Template
Top is
8 EIA
units from
base line
)URQW
Install rack nuts at
holes 9 and 13 up
from base line
Base line
Install rack nuts at
holes 6 and 19 up
from base line
Install rack nuts at
holes 11 and 15 up
from base line
Figure 8-3. Marking the Columns for Rack Nuts