ESP904 DB-9 Pin-outs in RS-422 Mode 
 
RS-422 
Signal Name 
 
Direction 
 
RS-422 
DB9M 
Pin 
Receive Data A (−) In 
RXDA 
(−) 1 
Receive Data B (+) 
In 
RXDB (+) 
Transmit Data B (+) 
Out 
TXDB (+) 
Transmit Data A (−) Out 
TXDA 
(−) 4 
Signal Ground 
--- 
GND 
Clear to Send A (−) In 
CTSA 
(−) 6 
Clear to Send B (+) 
In 
CTSB (+) 
Request to Send B (+) 
Out 
RTSB (+) 
Request to Send A (−) Out 
RTSA 
(−) 9 
Figure 47. RS-422 Connections in a DB-9 Connector 
 RS-422 
Connections 
62 
Appendix B 
Manual Documentation Number: ESP904-0504 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
 
 
Figure 48. RS-422 Connections with Flow Control 
In the RS-422 mode, TXD lines are outputs and RXD lines are inputs. 
Connect the ESP904 TXDB(+) line to the RXDB(+) line of the serial device, 
and the ESP904 TXDA(-) to the RXDA(-) of the serial device. 
If Flow Control is set for RTS/CTS, connect the ESP904 RTSB(+) to 
CTSB(+) of the serial device and the ESP904 RTSA(-) line to the CTSA(-) 
of the serial device. Connect from the ESP904 CTSB(+) line to the RTSB(+) 
of the serial device and from the ESP904 CTSA(-) line to the RTSB(+) line 
of the serial device. 
If connecting to Receive Only RS-422 devices, connect from the ESP904 
TXDB(+) and TXDA(-) lines to the receive pairs on all serial devices. 
Ground is signal ground and provides a common mode reference for the RS-
422 Receiver and Transmitters. 
N
N
o
o
t
t
e
e
:
:
 
 
 
The RS-422 mode can be used for full duplex 4-wire RS-485 operation provided 
that the ESP904 is acting as a sole master connecting to all the slave devices, 
and all slave devices share the Receive signal lines to the master. Set Flow 
Control for none, and omit connections to RTS/CTS line pairs. 
ESP904 pin-out 
in RS-422 mode 
 RS-422 
 
Device 
RS-422 Signal Names 
DB-9 
Pin# 
Connections
Signal 
Receive A (-) 
RXDA(-) 
 
TDA(-) 
Receive 
(+) 
RXDB(+) 2  
TDB(+) 
Transmit B (+) 
TXDB(+) 
 
RDB(+) 
Transmit A (-) 
TXDA(-) 
 
RDA(-) 
Ground GND 
  GND 
Clear to Send A (-) 
CTSA(-) 
 
RTSA(-) 
Clear to Send B (+) 
CTSB(+) 
 
RTSB(+)
Ready to Send B (+)  RTSB(+) 
 
CTSB(+)
Ready to Send A (-) 
RTSA(-) 
 
CTSA(-)