Fujitsu fi-6010N User Manual

Page of 21
17
If some other error occurs
• Message
An error has occurred. Try turning the power off 
and back on again. The administrator should 
contact the FUJITSU scanner dealer or an autho-
rized FUJITSU scanner service provider for 
help. [alphanumeric eight digits]
• Action
Try the following:
• If the scanner does not restart automatically, 
press the [Shutdown] button on the "Login" 
screen to turn the power off, and turn the 
power back on again to restart the scanner.
• If the error status persists after the scanner is 
restarted, press the [Shutdown] button on the 
"Login" screen, disconnect the AC cable 
from the scanner to turn the power off, wait 
for at least ten seconds, then reconnect the 
AC cable and try turning the power back on 
again. If the error status persists, contact 
your FUJITSU scanner dealer or an 
authorized FUJITSU scanner service 
provider.
fi-6010N Network Scanner Getting Started
18
Appendix A
Calibrating the Touch Panel
This should be done if and when the touch panel 
responses seem out of alignment with the positions of 
objects on the LCD screen.
1. Login as the administrator.
For details, refer to "3.1 Logging in" (page 6).
⇒ The "System Settings" screen appears.
2. Select the [System Settings] tab on the top 
menu.
3. Select the [Screen Calibration] tab on the left 
side menu.
⇒ The "Calibration Screen" appears.
4. Press the [Calibrate Screen] button. 
⇒ A blank calibration screen appears, with a red 
"+" (adjustment mark) in the top-left corner.
5. Touch the "+" with your fingertip.
Repeat until the test screen appears, with the fol-
lowing "Calibration" dialog box: 
6. Trace a line on the screen with your fingertip.
⇒ A corresponding line will appear on-screen.
If the line does not appear correctly, press the 
[Calib screen] button to return to Step 5.
If the screen becomes cluttered, press the 
[CLR screen] button to remove all the lines. 
The [Cursor on/off] button cannot be used.
7. When you are satisfied with the touch screen 
response, press the [Update] button.
⇒ This saves the current calibration data, com-
pleting the calibration process, and returns you 
to the "Screen Calibration" screen.
After being touched, the "+" will move to 
the next calibration position. Each time 
it stops, touch it again.
HINT
The keyboard may also be used on the 
calibration screen:
Press the [Home] key to jump straight to 
the post-calibration test screen.
Use the arrow keys to move the "+" 
to a different calibration point. This 
allows a bad touch to be redone.
Press the [Esc] key to stop the cali-
bration process and return to the 
"Screen Calibration" screen.
Press the [Enter] key to close the 
error dialog. (Not normally needed.)
ATTENTION
If the calibration is not performed 
carefully, or the [Enter] key is pressed 
before all the calibration points have 
been touched, the following error 
message may appear:
Parameter Error. Please input, again
Press the [Enter] key to dismiss the 
error dialog, and perform the calibra-
tion again, being careful to touch each 
calibration point accurately.