Honeywell 1450g User Manual

Page of 206
3 - 13
Scan one of the bar codes below to set the scanner’s power output to Full Power (100%), Medium Power (35%), Medium Low 
Power (5%), or Low Power (1%).   Default = Full Power.
Batch Mode
Batch mode is used to store bar code data when a scanner is out of range of its base or Access Point, or when performing 
inventory.  The data is transmitted to the base or Access Point once the scanner is back in range or when the records are man-
ually transmitted.  
Note: Batch mode has limitations when using multiple scanners to one base or Access Point.  If a cordless system is being used 
in "multiple link mode," where up to 7 scanners are to be connected to one base or Access Point, some accumulated or 
batched scans could be lost if scanners are constantly being moved in and out of range.
Automatic Batch Mode stores bar code data when the scanner is out of range of the base or Access Point.  The data is auto-
matically transmitted to the base or Access Point once the scanner is back in range.  When the scanner’s buffer space is full, 
any bar codes scanned generate an error tone.  In order to scan bar codes again, the scanner must be moved back into range 
of the base or Access Point so data can be transmitted. 
Inventory Batch Mode stores bar code data, whether or not you are in range of the base or Access Point.  To transmit the 
stored data to the base or Access Point, either place the scanner in the base, or scan 
When the scanner’s buffer space is full, any bar codes scanned generate an error tone.  In order to scan bar codes again, the 
data must be transmitted to the base or Access Point.  Once the data is transmitted, it is cleared in the scanner.
Persistent Batch Mode is the same as Inventory Batch Mode, except that once the data is transmitted to the base or Access 
Point, it is retained in the scanner.  If you want to transmit more than once, you can do so using this mode.  In order to clear the 
scanner’s buffer, you must scan 
.
Default = Batch Mode Off.
* Full Power
Medium Power
Medium Low Power
Low Power
* Batch Mode Off
Automatic Batch Mode