Intermec SR60 User Manual

Page of 174
Chapter 4 — Enabling and Configuring Symbologies
112
SR60 Scanner Programmer’s Reference Manual
Code 93 Options
This section describes the Code 93 options and contains the 
programming bar codes you can use to configure those options.
About Code 93 Options
The Code 93 symbology has the following programmable 
features:
• Minimum Label Length
• Read  Verification
Minimum Label Length
Minimum Label Length
 
sets the minimum label length required 
for Code 93 symbology. This feature causes the scanner to ignore 
small label segments, reducing the possibility that a portion of a 
good label is incorrectly seen as an entire label.
Read Verification
Read Verification
 
is the number of times the scanner is required 
to read the bar code data before sending the label data to the host.
Two Reads
 ---------
Three Reads
 ---------
Four Reads
 ---------
END ------------------------------------------