Intermec SR60 User Manual

Page of 174
Chapter 4 — Enabling and Configuring Symbologies
126
SR60 Scanner Programmer’s Reference Manual
length to 16. If you select variable length format, there is one 
more bar code label to scan:
• The Set Minimum Label Length bar code on page 128 
selects the minimum label length that the scanner will 
recognize. The minimum label length for this symbology 
must be between 04 and 16. Set the Minimum Length as 
high as your application allows.
• The Enable Fixed Length Format bar code on page 129 
directs the scanner to read only one or two label lengths. If 
you select fixed length format, there are three bar code labels 
for programming your scanner to read either one or two fixed 
lengths. The labels are:
• The Set First Fixed Length bar code on page 130 instructs 
the scanner that the next two programming labels scanned 
will define the first fixed label length. This setting must be 
between 04 and 16 characters.
• The Set Second Fixed Length bar code on page 130 
instructs the scanner that the next two programming 
labels scanned will define the second fixed label length. 
This setting must be between 04 and 16 characters.
• The No Second Fixed Length bar code on page 130 
configures the scanner to recognize only the label length 
chosen as the first fixed length.
Read Verification
Read Verification is the number of times the scanner is required 
to read the bar code data before sending the label data to the host.
Configuring the MSI /Plessey Options
Scan the following bar codes to configure the MSI/Plessey 
symbology options.
Check Digit
SET ------------------------------------------