Problem
Suggestion
APCO P25 CARD 
NOT INSTALLED  
appear when the scanner 
is turned ON.
Neither 
APCO P25 
CARD INSTALLED 
9600 SYSTEM nor 
APCO P25 CARD 
NOT INSTALLED 
appear when the scanner 
is turned ON.
Scratchy or robotic sound 
is heard during 
communications.
Digital communication is 
not heard.
DATA sound is heard at 
the beginning of digital 
communications.
Robotic sound is heard.
When 
CARD ERROR 
appears every 10 seconds 
while you are using P-25 
Card.
1. Check to see if the P-25 Card is properly installed.
1. Check to see if the P-25 Card Mode is 
1:ENABLE or 
2:DISABLE in the Menu mode.
1. Move to a location where the signal strength is strong.
2. Modulation accuracy of transmissions sent can be low.
1. Verify the accuracy of the frequencies of the P-25 system you 
are trying to monitor.
2. You might be in a dead-spot for the P-25 system you are trying 
to monitor. Check other locations in the area.
1. APCO project 25 systems can send data before voice 
communication.
2. Data sound can be heard when signal strength is weak.
1. Check to see if the 
ENC message appears on the display.
The scanner doesn’t monitor encrypted voice communications.
1. Re-install the P-25 Card.
If you still cannot get satisfactory results while using your scanner or if you want additional
information, please call or write the Uniden Parts and Service Division. The address and
phone number is listed in the warranty at the end of this manual. If you would like immediate
assistance, please call Customer Service at (800)297-1023.
If you have internet access, you can visit scanner.uniden.com for additional information.