Motorola DS6707 User Manual

Page of 402
10 - 50 Symbol DS6707 Digital Imager Scanner Product Reference Guide
CLSI Editing
Parameter # 36h
Enable this to strip the start and stop characters and insert a space after the first, fifth, and tenth characters of a 
14-character Codabar symbol. Enable this feature if the host system requires this data format.
NOTIS Editing
Parameter # 37h
Enable this to strip the start and stop characters from a decoded Codabar symbol. Enable this feature if the host 
system requires this data format. 
NOTE
Symbol length does not include start and stop characters.
Enable CLSI Editing
(01h)
*
Disable CLSI Editing
(00h)
Enable NOTIS Editing
(01h)
*
Disable NOTIS Editing
(00h)