Motorola DS6708 User Manual

Page of 458
RS-232 Interface
7 - 5
RS-232 Host Parameters
Various RS-232 hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu, Wincor-Nixdorf 
Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed in 
Table 7-2    
 Terminal Specific RS-232
Parameter
ICL
Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf Mode 
B/OPOS/JPOS
Olivetti
Omron
Transmit Code ID
Yes
Yes
Yes
Yes
Yes
Yes
Data Transmission 
Format
Data/Suffix
Data/Suffix
Data/Suffix
Data/Suffix
Prefix/Data/
Suffix
Data/Suffix
Suffix
CR (1013)
CR (1013)
CR (1013)
CR (1013)
ETX (1002)
CR (1013)
Baud Rate
9600
9600
9600
9600
9600
9600
Parity
Even
None
Odd
Odd
Even
None
Hardware 
Handshaking
RTS/CTS 
Option 3
None
RTS/CTS
Option 3
RTS/CTS 
Option 3
None
None
Software 
Handshaking
None
None
None
None
Ack/Nak
None
Serial Response 
Time-out
9.9 Sec.
2 Sec.
9.9 Sec.
9.9 Sec.
9.9 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
7-Bit
8-Bit
Beep On <BEL>
Disable
Disable
Disable
Disable
Disable
Disable
RTS Line State
High
Low
Low
Low = No data 
to send
Low
High
Prefix
None
None
None
None
STX (1003)
None
*In the Nixdorf Mode B, if CTS is low, scanning is disabled. When CTS is high, scanning is enabled.
** If you scan Nixdorf Mode B without connecting the digital scanner to the proper host, it may appear 
unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the 
digital scanner.