13 - 66 Symbol DS6708 Digital Scanner Product Reference Guide
GS1 DataBar Expanded
Parameter # F0h 54h.
Convert GS1 DataBar to UPC/EAN
Parameter # F0h, 8Dh
This parameter only applies to GS1 DataBar-14 and GS1 DataBar Limited symbols not decoded as part of a 
Composite symbol. Enable this to strip the leading '010' from DataBar-14 and DataBar Limited symbols encoding a 
single zero as the first digit, and report the bar code as EAN-13.
For bar codes beginning with two or more zeros but not six zeros, this parameter strips the leading '0100' and 
reports the bar code as UPC-A. The UPC-A Preamble parameter that transmits the system character and country 
code applies to converted bar codes. Note that neither the system character nor the check digit can be stripped. 
*
Enable GS1 DataBar Expanded
(01h)
Disable GS1 DataBar Expanded
(00h)
Enable Convert GS1 DataBar to UPC/EAN
(01h)
*
Disable Convert GS1 DataBar to UPC/EAN
(00h)