Motorola DS6708 User Manual

Page of 458
2 - 2
Symbol DS6708 Digital Scanner Product Reference Guide
Beeper Definitions
The digital scanner issues different beep sequences and patterns to indicate status. 
 defines beep 
sequences that occur during both normal scanning and while programming the digital scanner.
Table 2-1    
Beeper Definitions
Beeper Sequence
Indication
Standard Use
Low/medium/high beeps
Power up.
Short high beep
A bar code symbol was decoded (if decode beeper is enabled).
4 long low beeps
A transmission error was detected in a scanned symbol. The data is ignored. This 
occurs if the digital scanner is not properly configured. Check option setting.
5 low beeps
Conversion or format error.
Low/high/low beeps
ADF transmit error. See 
.
High/high/high/low beeps
RS-232 receive error.
Parameter Menu Scanning 
Low/high/low/high beeps
Out of host parameter storage space. Scan 
Short high beep 
Correct entry scanned or correct menu sequence performed.
Low/high beeps
Input error; incorrect bar code, programming sequence, or Cancel scanned; 
remain in ADF program mode.
High/low beeps 
Keyboard parameter selected. Enter value using numeric bar codes.
High/low/high/low beeps
Successful program exit with change in parameter setting.
Code 39 Buffering
High/low beeps
New Code 39 data was entered into the buffer.
3 long high beeps
Code 39 buffer is full.
Low/high/low beeps
The Code 39 buffer was erased or there was an attempt to clear or transmit an 
empty buffer.
Low/high beeps
A successful transmission of buffered data.
Macro PDF
2 long low beeps 
File ID error. A bar code not in the current MPDF sequence was scanned.
3 long low beeps 
Out of memory. There is not enough buffer space to store the current MPDF 
symbol.
4 long low beeps 
Bad symbology. Scanned a 1D or 2D bar code in a MPDF sequence, a duplicate 
MPDF label, a label in an incorrect order, or trying to transmit an empty or illegal 
MPDF field.
5 long low beeps 
Flushing MPDF buffer.