4) Imager Field of View & Resolution
The LH2’s dual field optical system may be modified based on your scanning environment. 
The LH2’s mega pixel imager may be set to the following two modes:
SXGA  Mode:  In  standard  SXGA  mode  (default),  the  1.3  Million  Pixel  imager  is  divided 
into near field and far field decode zones. In each zone the resolution is 1024 x 640 pixels 
(see figure 3.2).   In this mode of operation, the highest resolution, and therefore, widest 
working  range  on  symbols  of  all  densities  is  achieved.    The  trade-off  is  the  amount  of 
time the reader spends processing the image.  This time can be reduced by optimization 
functions.
If  only  the  near  field  is  used  (small,  high  density  symbols),  the  far  field  image  can  be 
ignored.  If only the far field is used (large, lower density symbols), the near field can be 
ignored.   Further optimization may be obtained by “windowing” the field to a smaller area.  
Each focal area may be narrowed by enabling the windowing feature found in Appendix 
A. 
VGA Mode:  In VGA mode (optional selection), the 1.3 Million Pixels are sampled on a 4-
to-1 basis.  This greatly reduces the amount of time necessary for the transfer of the image 
to the CPU and the resulting processing time (figure 3.3).  The trade-off for this increased 
speed is a reduction in resolution and working range.
NOTE: In the following section the LH2 can ONLY be programmed 
by  scanning  the  bar  codes.    For  detail  serial  commands  read  the 
Appendix A - Optimization Matrix section.