Searching and Storing
with the lowest frequency in the search range you select 
to the highest frequency in the range.
Notes: 
• Search ranges are preset. See “Editing a Custom 
Search Range” on Page 82 to change the range.
• You cannot turn off all custom search ranges.
1. Press 
 then turn the scroll control until Search 
For ...
 appears. Then press E. Or, press 
 + 
Scan/Srch, then select No. One of the search feature 
options appear.
2. Turn the scroll control until CUSTOM Search appears, 
then press E to select it. The scanner starts custom 
search of the custom search range you selected, 
stopping on any transmission it finds and displaying 
the frequency. Turn the scroll control to change the 
search direction. An arrow appears, showing the 
current search direction.
To turn search ranges on or off, press 0 and 1-9
To hold searching, press Hold. To resume searching, 
press  
then 
press 
Scan/Srch or Hold again. 
To lock out a frequency found while searching, press 
L/O. Search Lockout? appears. Press E to lock out 
the frequency or No to continue monitoring.
If you turn off the active custom search range, the 
scanner skips to the next custom search range and 
continues searching.
Note: If all frequencies in all active custom search 
ranges are locked out, All Locked! appears and the 
scanner does not stop.
Editing a Custom Search Range
You can edit up to 10 custom search ranges. The names 
of the custom search ranges appear on the display. The 
default custom search range names appear as CUSTOM 1, 
CUSTOM 2
, and so on.
Menu
Func
Func