10-8
Convert All Bar Codes to Code 39
By default, the Wand Emulation interface sends data to the attached host in the same symbology that was decoded. This can be a 
problem for customers with older systems that do not recognize newer symbologies (for example, RSS).
Enabling this parameter ignores the original symbology decoded, and outputs the data as if it were a Code 39 bar code. Any lowercase 
characters in the original data stream are transmitted as uppercase characters. This also allows ADF Formatting.
If Ignore Unknown Characters is enabled, any characters that do not have a corresponding character in the Code 39 symbology 
set are replaced by a space.
If Ignore Unknown Characters is disabled, if any characters that do not have a corresponding Code 39 character are encountered, 
the digital scanner emits an error beep and no data is transmitted.
ADF Note:  By default, the Wand Emulation interface does not allow scanned data to be processed by ADF 
rules.  Enabling this parameter allows the scanned data to be processed by ADF rules (
Enable Convert to Code 39 for Wand Host
*
Disable Convert to Code 39 for Wand Host
Note