46 | A
PPENDIX 
D:
 
D
ECODE 
Z
ONE
 
 
SDSC 3P 
 
Typical Working 
Ranges 
Guaranteed 
Working Ranges 
Symbol 
Density/ Bar 
Code Type/ W-
N Ratio 
Bar Code 
Content/ 
Contrast 
Note 1
 
Near 
Far 
Near 
Far 
4.0 mil  
Code 39; 2.5:1 
ABCDEFGH 
80% MRD 
1.00 in 
2.50 cm 
5.50 in 
13.97 cm 
2.20 in 
5.59 cm 
3.20 in  
8.13 cm 
5.0 mil  
Code 39; 2.5:1 
ABCDEFGH 
80% MRD 
1.25 in 
3.18 cm 
8.00 in 
20.32 cm 
2.20 in 
5.59 cm 
5.50 in 
13.97 cm 
7.5 mil  
Code 39; 2.5:1 
ABCDEF  
80% MRD 
1.50 in 
3.81 cm 
13.00 in 
33.02 cm 
2.00 in 
5.08 cm 
9.50 in 
24.13 cm 
10 mil 
Code 39; 2.5:1 
ABCDE  
90% MRD 
1.50 in 
3.81 cm 
18.00 in 
45.72 cm 
1.75 in 
4.45 cm 
14.00 in 
35.56 cm 
13 mil  
100% UPC 
12345678905 
90% MRD 
1.50 in 
3.81 cm 
24.00 in 
60.96 cm 
1.75 in 
4.45 cm 
18.00 in 
45.72 cm 
15 mil  
Code 39; 2.5:1 
ABCD  
80% MRD 
1.50 in 
3.81 cm 
28.00 in 
71.12 cm 
1.75 in 
4.45 cm 
21.00 in 
53.34 cm 
20 mil  
Code 39; 2.2:1 
123  
80% MRD 
1.75 in 
4.45 cm 
33.00 in 
83.82 cm 
27.00 in 
68.58 cm 
40 mil  
Code 39; 2.2:1 
AB  
80% MRD 
36.00 in 
91.44 cm 
28.00 in 
71.12cm 
55 mil  
Code 39; 2.2:1 
CD  
80% MRD 
45.00 in 
114.30 cm 
X 
34.00 in 
86.36 cm 
 
 
Notes: 
1.  CONTRAST measured as Mean Reflective Difference (MRD) at 650 nm. 
2.  Near ranges on lower densities (not specified) are largely dependent upon 
the width of the bar code and the scan angle. 
3.  Working range specifications at ambient temperature (23°C), Photographic 
quality symbols. pitch=10°, roll=0°, skew=0°, ambient light < 150 ft-candles. 
4.  X - Dependent on width of bar code. 
5.  Distances measured from front edge of chassis.