Ricoh 337943-003 User Manual

Page of 36
PostScript Languange Printer Commands 1-15
Device Parameters of Type /FileSystem
File system access from PostScript programs is described in Sections 3.8.2 and 3.8.3 of 
the Reference Manual and Section 3.3 of the Supplement.
Parameters for Disk
The factory default values for the 
%disk%
 device parameters are shown below.
%disk%
 Device Parameters 
Key
Type
Default For 
More 
Information
BlockSize *
integer
1024
See Section 3.3 of the Supplement.
Bus*
name
%scsi%
See Section 3.3 of the Supplement.
Free** 
§
integer
disk-dependent
See Section 3.3 of the Supplement.
HasNames*
boolean
true
See Section 3.3 of the Supplement.
InitializeAction
 
integer
0
See Section 3.3 of the Supplement.
Interleave*
integer
5
See Section 3.3 of the Supplement.
LogicalSize
§ 
**
integer
disk-dependent
See Section 3.3 of the Supplement.
Mounted
boolean
true
See Section 3.3 of the Supplement.
PhysicalSize** 
§
integer
disk-dependent 
See Section 3.3 of the Supplement.
PrepareAction
integer
0
See Section 3.3 of the Supplement.
Removable*
boolean
false
See Section 3.3 of the Supplement.
Searchable
boolean
true
See Section 3.3 of the Supplement.
SearchOrder
integer
0
See Section 3.3 of the Supplement.
Type*
name
/FileSystem
See Section 3.3 of the Supplement.
Writable
boolean
true
See Section 3.3 of the Supplement.
§ Value is derived from the disk media.
* Value is a read-only constant.
** Value is read-only but changes.
Device %disk0% is on the %scsi% bus.