PSC 1400I User Manual

Page of 180
General Features
2-4
Magellan
®
 1400i
Label Gone Timeout
This feature sets the time after the last label segment is seen before the scanner prepares for a 
new label.
PDF Label Gone Timeout
This setting specifies how long the 
 timer runs when specifically collecting 
PDF label segments prior to discarding data.
START / END
PROGRAMMING BAR CODES
Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To 
configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Label Gone Tim-
eout,” followed by three digits (zero padded) from the Alphanumeric table in 
desired time value. Exit programming mode by scanning the “START/END” bar code again.
DEFAULT SETTING FOR THIS FEATURE: 200 milliseconds (020)
Set Label Gone Timeout
START / END
PROGRAMMING BAR CODES
Sets the label gone timeout duration using hex values from 001 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To 
configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set PDF Label Gone 
Timeout,” followed by three digits (zero padded) from the Alphanumeric table in 
 representing the 
desired time value. Exit programming mode by scanning the “START/END” bar code again.
DEFAULT SETTING FOR THIS FEATURE: 1.5 Seconds (150)
Set PDF Label Gone Timeout