PSC 1400I User Manual

Page of 180
Programming
Product Reference Guide
                           1-3
Wand Emulation Connection — 
Connect the scanner to the appropriate port on the termi-
nal/PC via a decoder
1
 using the correct cable for the interface type you ordered. Reference 
.
IBM Connection — 
Connect the scanner to the IBM port on the terminal/PC using the cor-
rect IBM cable. Reference 
.
Keyboard Wedge Connection — 
Before connection, turn off power to the terminal/PC. 
The Keyboard Wedge cable has a ‘Y’ connection from the scanner. Connect the female to the 
male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. 
Reference 
.
Programming
The scanner is typically factory-configured with a set of default features standard to the interface 
type you ordered. After scanning the interface bar code from the 
 sec-
tion, you can select other options and customize your scanner through use of the instructions 
and programming bar codes available in that section and also the 
chapters of this manual.
Using the Programming Bar Codes
This manual contains feature descriptions and bar codes which allow you to reconfigure your 
scanner. Some programming bar code labels, like the label below for resetting defaults, require 
only the scan of that single label to enact the change. Most of the programming labels in this 
manual, however, require the scanner to be placed in Programming Mode prior to scanning 
them. Scan a START/END bar code once to enterProgramming Mode. Once the scanner is in 
Programming Mode, you can scan a number of parameter settings before scanning the START/
END bar code a second time, which will then accept your changes, exit Programming Mode 
and return the scanner to normal operation.
Resetting the Standard Product Defaults
If you are unsure of what programming options are in your scanner, or you’ve changed some 
options and want the factory settings restored, scan the Standard Product Default Settings bar 
code below (you do not have to scan START/END bar codes when scanning the Standard Prod-
uct Default Settings bar code). This will copy the factory configuration for the currently active 
interface to the current configuration.
The programming section lists the factory default settings for each of the menu commands for 
the standard RS-232 interface in 
BOLD
 text on the following pages. Exceptions to default set-
tings for the other interfaces can be found in 
.
1. Wand Emulation requires a decoder.
Standard Product Default Settings