6.1.2 Bar Code Length Setting:
The following example illustrates how to set Code 39 with a minimum
length of 5 and a maximum length of 20:
* Scan “Enter Group 5”.
* Scan “F1” to select Code 39.
* Scan “MIN LENGTH” to enter minimum length setting.
* Scan “0” and “5” to select length 5.
* Scan “MIN LENGTH” to end minimum length setting.
* Scan “MAX LENGTH” to enter maximum length setting.
* Scan “2” and “0” to select length 20.
* Scan “MAX LENGTH” to end maximum length setting.
* Scan “Exit” to end setup.
6.1.3 Code ID Setting:
Each bar code symbology supported by the scanner has a default ID
character defined as below: (If you don’t know what is the label that
you’re scanning, you may use this feature to identify.)
Symbology
Pre-Defined
UPC-A
A
UPC-E
E
EAN-13
F
EAN-8
FF
I 2 of 5
I
S 2 of 5
H
Code 39
M
Codabar
N
Code 93
L
Code 128
K
UCC/EAN128
]C1
MSI
O
Code 32
T
Delta Code
D
Plessey Code
P
Label Code IV,V
B
China Postal Code
C