Polycom 1725-22886-001/A User Manual

Page of 24
 Calibrate the Annotation Box
 13
Calibrate the touch screen for Camera 3.
Camera 3 is typically the VCR or DVD player. 
However, even if you do not have a VCR or DVD 
player connected to your system, you must still 
calibrate the touch screen for Camera 3. (You 
must calibrate each available camera and video 
source because the system stores separate 
calibration data for each.)
To calibrate the touch screen for Camera 3:
1.
On the Polycom remote control, press 
 
Camera and select 3.
2.
Pick up a pen from the SMART tray.
3.
Press the 
 Keyboard button on the 
SMART tray to access the calibration screen.
4.
Use the pen to touch the center of the 
crosshair on the upper left of the screen.
If the PIP appears on the screen, use the 
remote control to turn it off because it can 
hide the crosshairs.
5.
Use the pen to touch the center of the 
crosshair on the lower right of the screen.
6.
Use the pen to touch the center of the 
crosshair on the upper right of the screen.
7.
Draw on the screen to check that the 
calibration worked correctly.
Calibrate the touch screen for Camera 4.
Camera 4 is typically the integrated computer. 
However, even if you do not have an integrated 
computer, you must still calibrate the touch 
screen for Camera 4 because it will be used for the 
annotation box whiteboard instead. (You must 
calibrate each available camera and video source 
because the system stores separate calibration 
data for each.)
2
CALIBRATE TOUCH SCREEN
TOUCH UPPER LEFT TARGET
CALIBRATE TOUCH SCREEN
TOUCH LOWER RIGHT TARGET
CALIBRATE TOUCH SCREEN
TOUCH UPPER RIGHT TARGET
3
Note
If you add a PC or laptop after you have 
already performed this step, or you 
switch to a different PC or laptop, you 
may need to perform this step again to 
recalibrate the touch screen.