Panasonic AWHE60HN User Manual

Page of 114
26
White balance adjustment
(continued)
p
qManual adjustment
(R gain and B gain adjustment)
White balance can be adjusted manually.
When performing the operations  
using the wireless remote control
p
 Steps 
1
 through 
6
 represent the procedure for selecting 
the “AWB A” or “AWB B” memory. They need not be taken 
if a selection has already been made.
1
Select Manual1, Manual2 or Manual3 as the 
shooting mode by following the procedure in 
“Selecting the shooting modes (scene files)” 
(page 11).
    Camera 
 Scene             Manual1
  Contrast
  Picture
  Color Matrix
 Return
2
Press the [] or [] button to bring the cursor 
to “Picture”.
3
Press the [] button.
The “Picture 1/2” sub-menu is displayed.
     Picture 1/2 
 Chroma Level            0
 AWB Mode            AWB A
  R Gain                 0
  B Gain                 0
 Detail               High
 Flesh Tone Mode       Off
 DNR                  High
 Return
4
Press the [] or [] button to bring the cursor 
to “AWB Mode”.
5
Press the [] button.
“AWB Mode” starts blinking.
6
Press the [] or [] button to change the AWB 
mode to be used to “AWB A” or “AWB B”, and 
press the [
] button to enter the selection.
7
Press the [] or [] button to bring the cursor 
to “R Gain” or “B Gain.”
8
Press the [] button to make the “R Gain” or 
“B Gain” value blink.
9
Press the [] or [] button to change the 
“RGain” or “BGain” numerical value, and press 
the [
] button to enter the setting.
When performing the operations using the controller
When the AW‑RP655 is connected:
1
Press the [R/B GAIN/PED] button several times 
so that the “GAIN” item is displayed on the LCD 
panel.
2
Adjust the R Gain value using the jog dial (L).
3
Adjust the B Gain value using the jog dial (R).
When the AW‑RP555 is connected:
Refer to the Operating Instructions of the controller.
When the AW‑RP50 is connected:
Refer to the Operating Instructions of the controller.