OmniTek 2.3 User Manual

Page of 128
Page 36 
OmniTek XR User Guide, Software Release 2.3 
The functionality of this Source toolbar is shown through the following block diagram. 
 
Where the system includes the Motion-Capture option, the source to the Analyzer 
module, the SDI monitor, the Monitor Output and the Serial Outputs can all be selected 
between Serial Input and the output from the Generator (video store). However, when 
operating in Dual Link mode, the source to the Analyzer module, the Monitor output and 
the Serial Outputs all must be the same i.e. they must either all look at the Generator 
output or all at the Serial Input. 
Note: 
This toolbar includes the facility to switch between full dual-link operation and a single-link 
mode in which either Link A or Link B is used as the input. This facility exists purely to 
provide a quick and easy way of switching between single- and dual-link modes 
depending on the input that is being analysed. If single-link operation is required for an 
extended period, you should select a single-link video format on the Video Standard 
toolbar as this offers slightly more functionality. 
Video Standard Toolbar 
 
The Video Standard toolbar has one function, which is to select the appropriate video 
standard. 
The toolbar has two forms – one used for basic XR systems (shown here) and the other 
used where the optional Dual Link module is present (see below). 
The toolbar provides a shortcut to selecting the video format through the Engineering 
Settings control window (see page 21). Using the drop down menu is identical to 
selecting the video format from the Video: General section of the Engineering Settings 
control window. The video lock is unchanged. (If required, the video lock can be set within 
the Video: General section of the Engineering Settings control window.) 
Ticking  Auto detect causes the format of the input stream to be identified by matching 
against the range of video standards supported by OmniTek XR. It also automatically 
switches the video lock to Serial lock.  Note: If Auto detect is subsequently cancelled, the  
unit will remain in Serial lock until changed through the Engineering Settings control window.  
Dual Link version  
 
The version of the Video Standard toolbar displayed for Dual Link systems includes a 
Dual-link tick box. Ticking this option enables the facility within OmniTek XR for handling 
dual-link input/output as well as single-link. 
Input B 
Input A 
Dual Link 
incorporating   
A/B switch 
Video Store 
Capture 
Source 
Select 
 Analyzer 
 Waveforms 
 Histogram 
 
Serial Output 
Dual Link 
Monitor 
 Output 
 
 SDI Monitor 
 Audio Status 
 Video Status 
 Data View