Troubleshooting (Basic)/Error Code/Message
Follow the instructions below when an error code or message appears. If the problem persists or if the error code/mes-
sage displayed is not shown here, contact your technical support office.
„
To start the Setup Utility
A
Restart the computer.
B
Press F2 or Del while [Panasonic] boot screen is displayed.
Error Code/Message
Error Code/Message
Solution
Bad System CMOS
An error has occurred in the memory of system settings. This occurs when the memory con-
tent is changed by an unexpected program operation, etc.
z
Start the Setup Utility and return the settings to the default values, and then change the set-
tings as necessary.
z
If the problem persists, the internal clock battery may need to be replaced. Contact your tech-
nical support office.
System CMOS 
Checksum Error
Invalid Year. System 
date restored to 01/01/
2008
The date and time settings are not correct.
z
Start the Setup Utility and set the correct date and time.
z
If the problem persists, the internal clock battery may need to be replaced. Contact your tech-
nical support office.
Error
Hard disk access is 
prohibited by "Hard 
Disk Lock". Please 
enter the Setup Utility 
and change the 
values correctly to 
permit access.
The hard disk access is prohibited.
z
Start the Setup Utility and select [Disabled] in [Hard Disk Lock] in the [Security] menu.
Press <F2> to enter 
setup
z
Write down the error details and press 
F2
 or 
Del
 to start the Setup Utility. Change the settings if nec-
essary.
Reboot and Select 
proper Boot device or 
Insert Boot Media in 
selected Boot device 
and press a key
The operating system is not installed in the floppy disk or the hard disk that you are going to boot from.
z
If using a floppy disk, change the disk to the one you can use for boot.
z
If using the hard disk, check if the hard disk is recognized in [Information] menu of the Setup 
Utility. If the hard disk is recognized, perform the reinstallation (ΠSupplementary Instructions 
for Windows XP
). If not, contact your technical support office.
z
If a device is connected to the USB port, disconnect the device, or set [Legacy USB Support] 
to [Disabled] in the [Advanced] menu of the Setup Utility.
Disk error
Press any key to 
restart
Extended RAM 
Module Failed
z
The RAM module is not inserted correctly. Turn off the computer, and confirm that the RAM 
module conforms to the recommended module, and reinsert it.
Standard RAM Failed
z
Contact your technical support office.
FAN ERROR
z
The cooling fan does not work correctly. Contact your technical support office.