Bosch 3922 988 43318 User Manual

Page of 172
  2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 10 - Installation Techniques
en | 10-1
Introduction Installation Techniques
 Chapter 10. Installation             
Techniques
10.1   Introduction Installation Techniques
The primary focus of this chapter is to provide system installation techniques, typical examples,  and 
system limitations for stand-alone and PC- controlled systems using the range of equipment described 
in 
The cable attached to each DCN unit forms the trunk-line cabling (‘daisy-chain’). This cable carries all 
the systems digital signals, up-down links and power supplies.  Its versatility  allows units to be ‘tapped-
off ’ anywhere throughout an installation, meaning that systems can easily be expanded without the 
need to change the system cabling.  The single cable handles as many as 16 up and 16 down high 
quality contribution, distribution and data channels or 15 up and 15 down plus four speech-quality 
intercom channels.  
Installation is simplified by the use of ready-made cables, and where needed trunk-line splitters and 
Tap-off units.
REMARK:
 Before attempting to install a DCN system read the following 
‘System design fundamentals’ . This chapter introduces the reader to DCNs power handling 
requirements and its control limitations.
10.1.1  System design fundamentals
The total number of system units in any installation is limited by the maximum power handling 
capacity and control capacity of the CCU (as well as the current consumed by individual system 
units).  Because each DCN unit is a current consuming device, each unit draws a certain amount of 
current, depending on its power consumption requirements. This value normally expressed in Watts 
has been simplified to help make the total power handling capacity of a system easier to calculate.
To overcome the limitations of a system, dedicated units with extension facilities are available to 
extend the systems power handling capabilities. Such units include an Extension Power Supply Unit 
LBB 4106/00 and an Audio Media Interface Unit LBB 3508/00.  Where more than 240 units are 
required, the system offers a Multi Central Control Unit (Multi-CCU) configuration (See 
for more information)