Bosch 3922 988 43318 User Manual

Page of 172
  2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 4 - Central Control Equipment 
en | 4-8
CU Protocol and Serial Port settings
4.6   CU Protocol and Serial Port settings
.
4.6.1  LBB 3500/05 Port 1 for Camera Control
In a single (stand-alone) CCU system only one COM-port (Port 1) is available: Default settings are;
8 data bits
No parity check
1 Stop bit
4.6.2  LBB 3500/15 and LBB 3500/35 (TCB 4) - Port 1 : DCN Control PC 
                                                                               Port 2 : Camera Control 
In a single (stand-alone) CCU systems two serial COM-ports (Port 1 and Port 2) are available.       
Both ports can be individually configured. Default settings are;
8 data bits
No parity check
1 Stop bit
NOTE: 
It is possible to select ‘Full’ protocol on both Port 1 and Port 2.  However this is NOT 
recommended due to processing power and memory limitations.
Table 4-5: LBB 3500/05 Protocol settings 
DIP-switch S14
D RA
Port 1
1
Switch
Switch
DP-1
DP-2
Not applicable
OFF
OFF
Terminal
OFF
ON
Not applicable
ON
OFF
Camera control*
ON
ON
* default settings for LBB 3500/05
Table 4-6:  LBB 3500/05 Baud rate settings
DIP-switch  S14
Port 1
Switch
Switch
DP-3
DP-4
9.6 K
OFF
OFF
19.2 K*
OFF
ON
57.6 K
ON
OFF
115.2 K
ON
ON
* default settings for LBB 3500/05
DIP-switch S14: Port 1 (default settings)
S14
ON
8 7 6 5 4 3 2 1
5 - 8
Not used
Table 4-7:  LBB 3500/15 and LBB 3500/15 Protocol settings 
DIP-switch S14
Port 1
Port 2
RT 
Switch
Switch
Switch
Switch
DP-1
DP-2
DP-5
DP-6
Simple (Open interface)
OFF
OFF
OFF
OFF
Terminal
OFF
ON
OFF
ON
Full ON*
OFF*
ON
OFF
Camera control
ON
ON
ON*
ON*
* default settings for LBB 3500/15 and LBB 3500/35
Table 4-8:   LBB 3500/15 and LBB 3500/35 Baud rate settings
DIP-switch S14
Port 1
Port 2
Switch
Switch
Switch
Switch
DP-3
DP-4
DP-7
DP-8
9.6 K
OFF
OFF
OFF
OFF
19.2 K
OFF
ON
OFF*
ON*
57.6 K
ON
OFF
ON
OFF
115.2 K
ON*
ON*
ON
ON
* default settings for LBB 3500/15 and LBB 3500/35
DIP-switch S14 (default settings)
ON
S14
8 7 6 5 4 3 2 1
Port 1 default
ON
S14
8 7 6 5 4 3 2 1
Port 2 default