Bosch 3922 988 43318 User Manual

Page of 172
  2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 5 - Control using PC
en | 5-5
LBB 3511/00 PC Card for Multi-CCU Systems
5.4.2  LBB 3511/00 DIP-switch S12 and S13 settings
DIP-switch S12
:
Assign cards digital input (0 - 31)
DIP-switch S13
:
Assign cards 1/O (Input/Output) address (04E0 HEX)
DIP-switch S12
IP switches to define the card’s ‘digital input’.
DIP-switch S13
NOTES: 
  
1.
Available addresses (HEX):  0100,  0140,  0200 (default), 0280.  
These addresses must be set with the DIP-switches and in the Config.sys file of the OS/2 
PC.
2.
Available interrupts IRQ:  3, 4, 5, 7, 9, 10 (default) and 12.
NOTE: These interrupts must be set  in the Config.sys file of the OS/2 PC.
Table 5-2: DIP-switch S12
LBB 3511/00 PC-card for Multi-CCU systems
SW 1
ON
OFF
Chairman priority tone ON (default)
Chairman priority tone OFF
SW 2
OFF
Reserved for card’s Master Address (IMPORTANT: must NOT be changed)
SW 3
OFF
Reserved for card’s Master Address (IMPORTANT: must NOT be changed)
SW 4
OFF
Reserved for card’s Master Address (IMPORTANT: must NOT be changed)
SW 5
OFF
Reserved for card’s Master Address (IMPORTANT: must NOT be changed)
SW 6
ON
OFF
Active microphones and requests will be permanently switched OFF if the 
priority function of the chairman’s unit is activated.
Active microphones will be switched OFF temporarily if the priority        
function of the chairman’s unit is activated (default)
SW 7
OFF
Reserved for card’s Master Address (IMPORTANT: must NOT be changed)
SW 8
OFF
Reserved for card’s Master Address (IMPORTANT: must NOT be changed)
S12
ON
8 7 6 5 4 3 2 1
IMPORTANT:
DO NOT CHANGE
Table 5-3: DIP-switch S13
LBB 3511/00 PC-card for Multi-CCU systems
DIP-switches to define the cards I/O address (default: 0200 HEX)
I/O  address
0100 HEX
0140 HEX
0200 HEX
0280 HEX
SW 1
OFF
OFF
OFF
OFF
SW 2
OFF
OFF
ON
ON
SW 3
ON
ON
OFF
OFF
SW 4
OFF
OFF
OFF
ON
SW 5
OFF
ON
OFF
OFF
SW 6
OFF
OFF
OFF
OFF
SW 7
OFF
OFF
OFF
OFF
SW 8
OFF
OFF
OFF
OFF
Actual address settings DIP switch S13
DIP-SWITCH S13
Address (0100HEX)
S13
ON
8 7 6 5 4 3 2 1
DIP-SWITCH S13
Address (0140HEX)
S13
ON
8 7 6 5 4 3 2 1
DIP-SWITCH S13
Address (0200HEX)
S13
ON
8 7 6 5 4 3 2 1
(default)
DIP-SWITCH S13
Address (0280HEX)
S13
ON
8 7 6 5 4 3 2 1