Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation  and Operating Manual | Chapter 6 - DCN Camera Control
en | 6-5
Allegiant Video Switcher
Camera Control
CCU  = 1 // COM-port 1 . . 4
Video = 2 // COM-port 1 . . 4
Other fixed settings are:
Baudrate = 19200
Databits
= 8
Parity = 
none
Stopbits
= 1
NOTE: 
 The default video switcher communication settings should NOT be changed
5. Communication settings:
1. Refer to DIP-switch S14 settings on the ‘Trunk Communication Board’ (TCB4 (see 
). 
2. For multi-CCU systems the correct settings must be present in the CCU_CFG file of the Multi-
CCU control software LBB 3586 (see 
3. The default communication settings of the video switcher are the same as used in a DCN       
stand-alone system.
6.1.4.5  Installation of Camera Control software on the temporary PC
1. Install the ‘Stand-alone’ Camera Control software package LBB 3562/00.
2. Use the software program to configure and set up camera positions. On completion, all data and 
configuration settings will be automatically downloaded to the CCU.
3. Once camera positions are configured remove the temporary PC and make a direct connection 
as follows:
Single CCU system:  direct connection between CCU and video switcher
 
). 
Multi-CCU system:   direct connection between Master-CCU and the video switchers                
(see
).
4. Refer to relevant software manual.
6.1.4.6  Installation of Camera Control in DCN system with PC control
1. Requires DCN software release version 8.0 or higher
2. Requires a permanent connection in the following systems:
Single CCU system:  direct connection between CCU and video switcher (see 
). 
Multi-CCU system:   direct connection between Master CCU PC and the video switchers (see 
).
3. Install software package LBB 3588/00 on the DCN control PC (server PC in a ‘Multi-PC system).
4. Refer to relevant software manual.