2. Water-Cooled Condenser
a) Connection to an Open Drain System
• Condenser water supply inlet is 1/" female pipe thread (FPT). A minimum of 3/8" OD 
copper tubing is recommended for the condenser water supply line.
• A condenser water supply line shut-off valve and drain valve should be installed.
• Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for 
the condenser drain line.
• In some areas, a back flow preventer may be required in the cooling water circuit.
FD-1001MWH(-C)
Condenser 
Connection 
to a Potable 
Water Supply
Separate piping to approved drain. 
Leave a -inch (5-cm) vertical air gap 
between the end of each pipe and the 
drain.
-inch 
(5-cm) air 
gap
Floor
Drain
Condenser Water 
Supply Inlet
1/" FPT
Condenser Drain 
Outlet 3/8" FPT
Icemaker/Condenser 
Water Supply Line 
Shut-Off Valve
Icemaker/Condenser 
Water Supply Line 
Drain Valve
Icemaker
Icemaker Water 
Supply Inlet
1/" FPT
Bin Drain Outlet 
3/4" FPT
Icemaker 
Drain Outlet 
3/4" FPT
To convert to top water supply, 
install the optional Top Water 
Supply Kit (HS-13).
Storage Bin
Fig. 15