Installation Clearances
Venting Requirements 
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed 
area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use a 3
¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular metal vent. Rigid 
metal vent is recommended. Plastic or metal foil vent is not 
recommended.
The length of vent system and number of elbows should be 
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent 
between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps or duct tape to seal all joints in the vent system.
The vent system must have a damper.
Use caulking to seal exterior wall or roof opening around the 
cap.
Cold Weather Installations
An additional back draft damper should be installed to minimize 
backward cold air flow and a thermal break should be installed to 
minimize conduction of outside temperatures as part of the vent 
system. The damper should be on the cold air side of the thermal 
break.
The break should be as close as possible to where the vent 
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of air 
movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in your 
area.
Venting Methods
Vent system can terminate either through the roof or wall. Use 
3
¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular with a maximum vent 
length of 35 ft (10.7 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates 
both back pressure and air turbulence that greatly reduce 
performance. 
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop
B. 18" (45.7 cm) to 24" (61.0 cm) suggested max. - bottom of range 
hood to cooking surface
C. 30" (76.2 cm) min. cabinet opening width for 30" (76.2 cm) 
models and 36" (91.4 cm) min. cabinet width for 36" (91.4 cm) 
models
D. 13" (33.0 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height
A
B
C
D
E
Roof Venting
Wall Venting
A. 3
¹⁄₄" x 10" (8.3 x 25.4 cm) 
rectangular vent through the 
roof. (purchased separately)
B. Roof cap with damper 
(purchased separately)
C. 18" (45.7 cm) min. to 
24" (61.0 cm) max. above the 
cooking surface
A. 3
¹⁄₄" x 10" (8.3 x 25.4 cm) 
rectangular vent through the 
wall or out the top (purchased 
separately)
B. Wall cap with damper 
(purchased separately)
C. 18" (45.7 cm) min. to 
24" (61.0 cm) max. above the 
cooking surface
A
B
C
A
B
C