Dacor DHI361 User Manual

Page of 16
11
i
nsTallaTion
 i
nsTruCTions
f
inal
 e
lectrical
 i
nStallation
 WARNINGS
To avoid electrical shock or fire hazard, make sure
the power supply at the fuse or junction box is turned
off before proceeding with final electrical installation.
Improper connection of the hood electrical wiring may
create an electric shock or fire hazard and may result
in damage to the hoods electrical system.
Do not ground the hood to the neutral (white) power
supply wire. Connect the hood ground wire to a
separate, properly grounded wire installed by a
licensed electrician.
Connect the house power supply wires to the wires 
coming out of the hood junction box, inside the 
chimney:
Connect the white wire from the hood to the neutral
1.
(white) power supply wire.
Connect the black wire from the hood to the hot (black)
2.
power supply wire.
Connect the green and yellow wire from the hood to
3.
the house ground (green) wire from the junction box.
BLACK TO BLACK
YELLOW/GREEN  
TO GREEN
WHITE TO WHITE
f
inal
 c
himney
 a
SSemBly
IMPORTANT: Be careful not to pinch the electrical wires
while assembling the chimney.
Move the chimney up toward the ceiling. Line up the
1.
holes on the side of the chimney, above the vents, with
the holes on the side of the mounting bracket.
Attach the sides of the chimney to the bracket using
2.
two machine screws, one on each side.
Carefully, slide the bottom portion of the chimney down
3.
until it rests on the top of the range hood.
Reinstall the range hood filter(s) before operation.