4.10  Automatic Protection Configuration
The Automatic Protection Configuration section is responsible for configuring the S/UNI-4x622
to use the APS ports.
Configuring APS Working/Protect Mate: suni4x622APSCfg
When enable is set, this function enables the S/UNI-4x622 to operate as an APS working/protect
mate under a failed condition. When enable is not set, this function resumes normal operation.
Prototype
INT4 suni4x622APSCfg(sSUNI4x622_HNDL deviceHandle,
UINT1 mode, UINT1 enable)
Inputs
deviceHandle
: device handle (from 
suni4x622Add
)
mode
:  =0 if working mate; =1 if protect mate
enable
             : start/stop APS operation
Outputs
None
Returns
Success = 
SUNI4x622_SUCCESS
Failure = 
SUNI4x622_ERR_INVALID_DEVICE_STATE
               
SUNI4x622_ERR_INVALID_DEV
Valid States
SUNI4x622_ACTIVE, SUNI4x622_INACTIVE
Side Effects
None
Configuring the Source Channel for the Given Channel Receive Path:
suni4x622RPCfg
The function is used to control the source channel for the receive path.
Prototype
INT4 suni4x622RPCfg(sSUNI4x622_HNDL deviceHandle,
UINT1 channel, UINT1 srcChan)
Inputs
deviceHandle
: device handle (from 
suni4x622Add
)
channel
: receive path channel number
srcChan
             : source channel number
Outputs
None
Returns
Success = 
SUNI4x622_SUCCESS
Failure = 
SUNI4x622_ERR_INVALID_DEVICE_STATE
               
SUNI4x622_ERR_INVALID_DEV
               
SUNI4x622_ERR_INVALID_CHAN
Valid States
SUNI4x622_ACTIVE, SUNI4x622_INACTIVE
Side Effects
None