DELL MD3660f User Manual

Page of 58
2
Controller Modules
RAID Controller Modules
The RAID controller modules provide high-performance, advanced virtual disk configuration, and fault-tolerant disk 
subsystem management. Each RAID controller module contains 2 GB of mirrored cache for high availability and is 
protected by a battery powered cache offload mechanism. RAID controller modules provide the following data path and 
enclosure management functions:
Monitoring and controlling enclosure environment elements (temperature, fans, power supplies, and enclosure 
LEDs)
Controlling access to the physical disks
Communicating enclosure attributes and states to the host server and management station
MD3260 SAS RAID Controller Module Features And Indicators
Figure 8. MD3260 SAS RAID Controller Module Features and Indicators
Item
Indicator, Button, or 
Connector
Icon
Description
1
Serial debug port
Dell support only.
2
Ethernet management port
Provides a 100/1000 Mbps Ethernet connection for out-of-band 
management of the enclosure.
3
Password reset switch
Pressing this switch resets the password.
4
Battery fault indicator
The battery fault indicator lights amber when battery backup unit 
or battery has failed.
5
Cache active or cache 
offload indicator
The cache active or cache offload indicator lights green when 
on-board controller memory contains data.
15