DELL E11J User Manual

Page of 14
NOTE: 
Heavy weight warning.
A fully configured MD1280 enclosure weighs up 
to 103.7 kg (287.5 lbs). An unpopulated 
enclosure weighs 64 kg (141 lb). Use appropriate 
lifting methods.
High temperature warning.
The operating temperature inside the enclosure 
can reach up to 60° C (140 °F). Be careful when 
opening drive drawers and removing carriers.
Electrical disconnection warning.
Indicates that all electrical supply connections 
to the enclosure should be disconnected before 
proceeding.
Unpacking the system
NOTE: Unpacking, installing, and deploying your Dell Storage must be carried out only by a certified 
service technician.
Before you begin, make sure the site where you intend to set up and use the Dell Storage has the 
following:
• 208 V power from an independent source or a rack power distribution unit with a UPS (110 V power 
will not work.).
• A 5U space in the lower 20U of the rack. If planning to install above the 20U mark, a customer-
provided mechanical lift must be made available.
Installation overview 
The installation process includes the following general tasks.
CAUTION: If installed in a closed-or multi-unit rack assembly, the operating ambient temperature 
of the rack environment may be greater than room ambient temperature. Therefore, install the 
equipment in an environment compatible with the maximum ambient temperature (Tma) 
specified by the manufacturer. For more information, see the Technical Specifications section in 
this document.
1.
Assemble the rails following the safety instructions and the rack installation instructions provided 
with your system.
2. Unpack the enclosure.
WARNING: Two people using lift straps are required to avoid injury.
3. Install the enclosures into the rack.
• Always load the rack from the bottom for weight stability.
• If you have fewer than the maximum number of enclosures, you can allow room for expansion.
4