Sanyo CVW-EXA124 User Manual

Page of 30
 
 
5
1  Specifications 
1.1  CVW-EXA284 (H: 84 7/8”, L: 96 3/8”) / CVW-EXA224 (H: 84 7/8”, L: 144 5/8”) 
Model Name 
CVW-EXA284 
CVW-EXA224 
General 
 
 
Application: 
Medium Temperature (Fresh Produce) 
Medium Temperature (Fresh Produce) 
Cooling Capacity: 
1224 BTU/h/ft.  (2,880W) 1224 
BTU/h/ft.  (4,321W) 
Discharge Air: 
34°F (1.11°C) 
34°F (1.11°C) 
Evaporator Temperature: 
28°F (-2.22°C) 
28°F (-2.22°C) 
Defrost (Off-cycle) 
Medium Temperature   
Medium Temperature   
Frequency: (times per day) 
6, once every 4 hours 
6, once every 4 hours 
Termination Temperature: 
50.0°F 
50.0°F 
Failsafe/Duration: 
30 minutes 
30 minutes 
Electrical 
 1-phase 
120V 
 
1-phase 120V 
Anti-condensation Heater: 
 
N/A N/A 
 
N/A N/A 
Standard: 
 
195W 2.28A 
 
285W 3.42A 
Fan 
Motor 
High Efficiency: 
 
84W 1.29A 
 
126W 1.93A 
Exterior: 
2 Rows of Lamps 
110W 0.94A 
2 Rows of Lamps 
166W 1.42A 
Top Panel 
N/A N/A 
Top Panel 
N/A N/A 
Interior: 
Handrail 
N/A N/A 
Handrail 
N/A N/A 
Lights 
Total: 
Standard 
110W 0.94A 
Standard 
166W 1.42A 
Components 
 
 
Anti-condensation Heater 
N/A 
N/A 
Standard: 
SPFBE141 x 3 
SPFBE141 x 3 , SPFBE91T x 2 
Fan 
Motor 
High Efficiency: 
SSC2B12CNHBV1 x 3 
SSC2B12CNHBV1 x 3 , SSC2B12BVHBV1 x 2 
Fan Blade Pitch: 
Inside:#128×2, Outside:#128 x 1 
Inside:#128 x 3, Outside:#117 x 2 
Illumination: 
FO32/XP (T8) (Output 32W) 
FO32/XP (T8) (Output 32W) 
Pipe Diameter: 
Liquid 3/8”, Suction 3/4” 
Liquid 3/8”, Suction 3/4” 
Measurements
 
 
 
Outer Dimensions: 
84 7/8” (H) × 42 1/2” (W) × 96 3/8” (L) 
84 7/8” (H) × 42 1/2” (W) × 144 5/8” (L) 
Open Space: 
61 1/2” 
61 1/2” 
Display Area: 
73.4 sq.ft. 
110.1 sq.ft 
Effective Capacity: 
72.0 cu.ft. 
108.0 cu.ft. 
Weight: 
620.5 lbs 
892.0 lbs 
Waste Outlet Dimensions: 
1 1/2” 
1 1/2”
 
 
 
Standard Ambient Conditions: Indoor temperature 75°F (24°C), relative humidity 55%, wind speed under 39.4 fpm. 
 
All specifications are based upon temperature, humidity, and wind speed values equal to or less than Standard Ambient Conditions. 
 
SANYO Cases described in this manual are designed for indoor use only. SANYO Cases should not be exposed to direct sunlight. 
 
Fan Motors are available in Standard-type (AC Fan Motors) or High Efficiency-type (DC Fan Motors). 
 
Display Area Effective Capacity data specification based on 4 (four) 20” shelves set at 0° (flat). Any variations from this specification will 
affect overall data.