DELL E09J User Manual

Page of 42
Item
Name
Icon
Description
6
AC power status 
indicator (2)
• Off: AC power is off, or the power is on but the module is 
not in a controller, or it may indicate a hardware fault
• Steady green: AC power is on
• Blinking green: AC power is on and the PSU is in standby 
mode
7
DC power fault 
indicator (2)
• Off: Normal operation
• Steady amber: A PSU has been removed, or there is a DC 
or other hardware fault, or there is a problem 
communicating with the PSU
• Blinking amber: PSU is in programming mode
8
Power socket (2)
Accepts a standard computer power cord.
9
Power switch (2)
Controls power for the storage system. There is one switch for 
each power supply/cooling fan module.
SCv2000/SCv2020 Storage Controller Features and Indicators 
The SCv2000/SCv2020 includes up to two storage controllers in two interface slots.
The storage controllers support Fibre Channel, iSCSI, or SAS front-end ports.
SCv2000/SCv2020 Storage Controller with Fibre Channel Front-End Ports
Features and indictors on a storage controller with Fibre Channel front-end ports.
Figure 3. Storage Controller with Four 8 Gb Fibre Channel Front-End Ports
Figure 4. Storage Controller with Two 16 Gb Fibre Channel Front-End Ports
Item Control/Feature
Icon Description
1
Battery status indicator
• Blinking green (on 0.5 sec. / off 1.5 sec.): Battery heartbeat
• Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is 
charging
10
About the SCv2000/SCv2020 Storage System