General Information
CS2000 Quick Start:
1. 
Connect red wire to supply voltage
2. 
Connect black wire to supply common
3. 
For NPN Output - connect orange wire to black wire
 
For PNP Output - connect orange wire to red wire
4. 
Connect white wire to your controller - refer to page 6 for wiring diagrams
5. 
Turn on power
6. 
Peel off a label and position the label backing (web) under the sensing area
7. 
Depress the push-button until the yellow LED comes on (1 sec.), then release
8. 
The yellow LED will begin flashing
9. 
Move a label under the sensing area and the green LED will come on
10.   The label sensitivity is now adjusted and the sensor should function correctly
11.   The yellow LED indicates when label backing (web) is detected
12.  The green LED indicates when label over label backing is detected
13.  The red LED indicates when the output is active - NPN sinking or PNP sourcing