Honeywell N431X User Manual

Page of 222
6 - 48
Default = Don’t Require Addenda.
EAN-13 Beginning with 434/439 Addenda
Required 
This setting programs the engine to require any combination of a 2 digit 
addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “434” 
or “439.”  The following settings can be programmed:
Require Addenda:  All EAN-13 bar codes that begin with a “434” or “439” 
must have a 2 digit addenda, a 5 digit addenda, or a combination of these 
addenda.  The EAN-13 bar code with the addenda is then transmitted as a 
single, concatenated bar code.  If the required addenda is not found within 
the 
 period, the EAN-13 bar code is discarded.
Don’t Require Addenda:  If you have selected Require Addenda, and 
you want to disable this feature, scan Don’t Require Addenda.  EAN-13 
bar codes are transmitted, depending on the setting you are using for 
Require 2 Digit Addenda
* Don’t Require Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda