2.2 Pressure Equipment Directive
The MSP400RH transmitter does not fall within the PED definition as enclosing a pressurised fluid, so is
therefore outside the scope of the Directive.
Accordingly, the Declaration of Conformity does not list the Pressure Equipment Directive.
2.3 Specifications
Materials of construction:
Transducer material
PVDF
Body & cover Material
Glass filled nylon
Cable gland
Nylon with Nitrile cable seal
Cover seal
Silicone rubber
Cover screws
316 Stainless Steel
Transducer bodyseal
EPDM
Electrical
Supply voltage
12-40V dc
Output
4-20mA (3.8 - 20.5mA linear)
Relays (2) : SPST rated 1A at 24Vdc
Communications
HART Digital communications (Rev. 5)
Earthing
None required
Recommended Cable
Two core each 0.22 mm
min, shielded
Max. cable length
3000m
Cable resistance
0.1 Ohm per metre length max.
Cable gland
Suitable for cable sizes 4mm - 8mm diameter
Operating
Range
0.45 to 11m
Temperature
Ambient
-40°C to +70°C
Wetside
-30°C to +70°C
Pressure
-0.25 bar to 3.0 bar
Weatherproofing
IP66/IP67
Certification
The MSP400 range of products are Factory Mutual (Fm) certified as Process Control Equipment meeting
basic electrical, mechanical and fire protection requirements (IP66/IP67).