Grizzly 9962ZX User Guide

Page of 80
-28-
G0445/G0582/G9962Z/9962ZX Wide Belt Sander
Table Calibration
Use the first board fed through the sander to test 
the accuracy of the digital thickness gauge. 
To calibrate the digital thickness scale:
1.  Using a properly set-up planer, plane a board  
to uniform thickness.   
2.  Lower the sander table far enough to place 
the planed board under the sander roller.
3.  Manually raise the table until the board just 
touches the sanding roller. 
4.  Remove  the  board  without  changing  the 
table  height.  This  ensures  the  table  will  be 
properly adjusted for the first sanding pass.
5.  Run  the  board  through  the  sander  several 
times  at  the  initial  height  setting.  Manually 
raise  the  table  0.020"  and  pass  the  board 
through  the  sander  several  more  times. 
Monitor the amperage meter and the result-
ing load on the sander.
6.  Measure  the  thickness  at  various  points 
around  the  board  using  a  precise  microm-
eter or set of calipers. Continue sanding the 
board  at  that  height  until  the  average  thick-
ness measurement is within 
+
- 
0.003".  
  
 
Note:  These  final  passes  should  be  done 
without  adjusting  the  table  height.  This 
ensures  the  most  consistent  average  thick-
ness.
7.  Observe the digital display read-out, it should 
indicate the average thickness of the sanded 
wood.
—If  it  does,  the  sander  is  properly  calibrated 
and accurate to the nearest 0.005".
 —If it does not, you must recalibrate the digital 
thickness scale.
 
To recalibrate the digital thickness scale: 
1.  Without  moving  the  table  height,  enter  the 
numerical measurement of the average thick-
ness of the sanded wood into the digital key 
pad on the control panel. 
 
Note: The average thickness of the sanded 
wood  should  now  be  flashing  on  the  digital 
read-out.
2.  Press and hold the      key until the display 
stops  flashing.  The  sander  is  now  correctly 
calibrated. 
SECTION 7: SERVICE 
Platen Service
To replace the platen felt and graphite pad:
1.  DISCONNECT  THE  SANDER  FROM  THE 
POWER SOURCE!
2.   Open the left access door, and use the platen 
tool, shown in 
Figure 23, to remove platen. 
3.   Replace platen felt pad and graphite pad.
4.   Reinsert the platen until it stops.
5.   Close the access door.
Figure 23. Removing platen.