Southbend SB1019 User Manual

Page of 56
For Machines Mfg. Since 8/09
Model SB1019
-43-
E L E C T R I C A L
Wiring Diagram
Hot
Hot
220 VAC
6-15 Plug
(As Recommended)
Pump
 Motor
GND
1
1
2
2
2
3
3
3
4
1
2
3
4
1
1
2
2
3
3
4
4
4
U2
U2
V2
V2
4
Start Capacitor
3MFD 450 VAC
Limit Switch
Motor Overload 
Reset Button
S. Cap
150MFD
250VAC
Saw Motor
110V
Rewired 
for 220V
110V
Rewired 
for 220V
(Note Jumper
Position)
Control
Box
Ground
Block
ON/OFF 
Switch
(Viewed From Above)
Neutral
Hot
Ground
110 VAC
5-15 Plug
Ground
1
2
3
4
1
2
3
4
U2
V2
220
VAC
Rewired for 220V
READ PAGE 41 BEFORE 
DOING ANY WIRING!