PREPARATION
For Machines Mfg. Since 8/09
Model SB1018
-9-
P R E P A R A T I O N
Preparation Overview
The purpose of the preparation section is to help 
you prepare your machine for operation. The 
list below outlines the basic process to follow 
to prepare your machine for operation. Specific 
steps for each of these points will be covered in 
detail later in this section.
The typical preparation process is as follows:
1.  Unpack the machine and inventory the 
contents of the carton.
2.  Clean the machine and its components.
3.  Make any necessary adjustments or 
inspections to ensure the machine is ready 
for operation.
4.  Connect the machine to the power source.
5.  Test run the machine to make sure it 
functions properly and is ready for operation.
Things You'll Need
The items listed below are required to 
successfully set up and prepare this machine for 
operation.
For Machine Setup
•  Wrench 12mm
•  Wrench 14mm
For Power Connection
•  A power source that meets the minimum
circuit requirements for this machine. (Refer 
to the Power Supply Requirements 
section for details.)
•  A qualified electrician to ensure a safe and
code-compliant connection to the power 
source.
Power Supply 
Requirements
Electrocution or fire may 
occur if machine is not 
correctly grounded and 
attached to the power 
supply. Use a qualified 
electrician to ensure a safe 
power connection.
Before installing the machine, consider the 
availability and proximity of the required power 
supply circuit. If an existing circuit does not meet 
the requirements for this machine, a new circuit 
must be installed.
To minimize the risk of electrocution, fire, 
or equipment damage, installation work and 
electrical wiring must be done by a qualified 
electrician in accordance with all applicable 
codes and standards.
Availability
The full-load current rating is the amperage 
a machine draws at 100% of the rated output 
power. On machines with multiple motors, this is 
the amperage drawn by the largest motor or sum 
of all motors and electrical devices that might 
operate at one time during normal operations.
The full-load current is not the maximum 
amount of amps that the machine will draw. If 
the machine is overloaded, it will draw additional 
amps beyond the full-load rating.
If the machine is overloaded for a sufficient 
length of time, damage, overheating, or fire may 
result—especially if connected to an undersized 
circuit. To reduce the risk of these hazards, 
avoid overloading the machine during operation 
and make sure it is connected to a power supply 
circuit that meets the requirements in the 
following section.
Full-Load Current Rating
Full-Load Rating at 110V .................. 8.6 Amps
Full-Load Rating at 220V .................. 4.3 Amps