SEcTiON 6: SERvicE
Troubleshooting
SYMPTOM
POSSiBLE cAUSE
POSSiBLE SOLUTiON
too little airflow in booth. 
1.  the filter is dirty. 
2.  obstructions exist in front of the 
filters.
3.  Filters do not meet design 
specifications.
4. Fan is dirty. 
5.  Filters not installed correctly.
1.  Change the filters.
2.  remove obstructions. 
3.  Change filters to meet correct 
specifications. 
4.  Clean fan.
5.  Make sure all filters are installed and 
properly seated.
too much airflow in booth.
1.  Filters are not correctly seated.
1.  Make sure all filters are installed and 
properly seated.
the filter indicator does not work 
properly.
1.  Fluid level is low.
2.  obstructions exist in hoses.
3.  air filter indicator is not level.
1.  Check fluid level and add fluid as 
needed.
2.  remove obstructions from hoses.
3.  loosen manometer mounting 
hardware, level using sight glass, 
and tighten mounting hardware.
Spray Booth Operations
SYMPTOM
POSSiBLE cAUSE
POSSiBLE SOLUTiON
reduced performance with new filters. 
1.  paint build-up on exhaust fan blades 
or exhaust duct. 
1. Check exhaust fan blades and 
exhaust duct and, if needed, clean 
with heavy-duty paint remover.
Motor producing unusual noise or 
vibrations.
1.  Motor mounting hardware loose or 
fan loose.
1.   tighten motor mounting hardware. 
tighten fan. 
Motor and Electrical
review the troubleshooting and procedures in this section to fix or adjust your machine if a problem devel-
ops. if you need replacement parts or you are unsure of your repair skills, then feel free to call our technical 