Alarm Output: Select an alarm output number. When an alarm is triggered, the signal will be 
transmitted through the selected alarm output relay.  
Output Type: Select an output type when an alarm is triggered. 
Timeout: Select this option and then set up the Timeout Duration in the field below, the 
alarm output will last for the setup duration time (1 ~ 150 seconds). 
Permanent: Alarm will remain active until the user presses the “Enter” key on the IR 
Remote Control or resets the alarm remotely. 
Transparent: Alarm output remains as long as the alarm input is active. 
Trans + Timeout: Alarm output continues until event ends, then continues for the setup 
duration time (1 ~ 150 seconds). 
Timeout Duration: This function only appears when you select Timeout or Trans + Timeout 
options in the Output Type drop-down list. Select a duration time for the motion event. The 
alarm output will last for the setup duration time between 1 and 150 seconds.  
Main Monitor: Select Full Screen to force the camera associated with the selected alarm 
number to display full screen on the Main Monitor. The full screen camera view will last 
according to the Output Type selected in the field above.  
Call Monitor:
 Select Full Screen to force the camera associated with the selected alarm 
number to display full screen on the Call Monitor. The full screen camera view will last 
according to the Output Type selected in the field above. 
Record: 
Select a camera to start recording when the associated alarm number is triggered. 
Input Type: Select an input type when the selected alarm number is triggered. The options 
include N.O. and N.C. 
Active Camera: This function is for associating an alarm trigger with a specific camera. For 
example, if you set up an external motion detector near Camera 2, you can select Camera 2 in 
this field. The alarm will be associated with this camera for full screen display, event logging 
and PTZ actions. 
PTZ:
 If the Active Camera selected above is a PTZ camera, you can further set up the PTZ 
actions in this field.  
Apply To: 