     To relieve fluid and air pressures:
     1. Push down Yellow slide valve, P/N 21402-00 to  bleed
         off air to system.
     2. Open P/N 21228-00 on catalyst pump to recirculation 
          position.
     3. Open P/N 21192-00 on bottom of material pump.
4. Verify the Trigger Lock is in the Locked position.
Daily Maintenance
It is recommended that the following service be per-
formed on a daily basis.
1.
 The Gun is built at the factory with, P/N 21222-00 
      Lubricate. This is a water soluble lubricate, not
      affected by most solvents. When maintaining the 
      Gun, it is recommended that this is used as outlined 
      on “Lubricate Page”. Clean the Gun using a brush 
      and a appropriate clean solvent.   
2.
 Inspect Gun Valve Needle shafts, making certain 
     they are clean and free of over-spray or foreign- 
     material. Clean and lubricate as required.
3.
 Inspect the Gun Packings, Needles and Seats for 
     catalyst or material leakage.  If leakage does occur, 
     correct at once! If material leaks (or drips) out of the 
     nose of the gun, this indicates that there is a bad needle
     /seat condition. If material leaks out of the back of the
     needle stem, this indicates loose or worn packings
     and may be repacked by tightening the packing nuts, 
     P/N 20509-00 1/8 turn each until leak stops. Test trigger 
     to verify spring can return needle to seat.
4.
 Maintain a reasonable stock level of “wear” items 
     such as Packings, Seals and O-Rings
5. 
If dispense gun is leak tested, be sure to dry gun 
      thoroughly.
6.
 
Never leave dispense gun immersed in any liquid. 