Preparation 
6
Preparation
Pressure Relief Procedure
To reduce risk of injury, follow this procedure 
whenever you see this symbol throughout this 
manual, Also, perform this procedure whenever 
you:
Stop spraying
Check or repair any part of this system
Install or clean spray nozzle
1.
Turn power switch (K) OFF.
2.
Trigger gun into material hopper.
3.
Open gun air valve.
Grounding and Electrical Requirements
This sprayer must be grounded. Grounding reduces the 
risk of electrical shock by providing an escape wire for 
the electrical current. The sprayer cord includes a 
grounding wire with an appropriate grounding plug. The 
plug must be plugged into an outlet that is properly 
installed and grounded in accordance with all local 
codes and ordinances.
Check with a qualified electrician or serviceman if 
grounding instructions are not completely understood, 
or if in doubt as to whether the product is properly 
grounded. Do not modify plug provided; if it will not fit 
the outlet, have proper outlet installed by a qualified 
electrician.
120V AC Systems
This equipment requires a 120V AC, 60 Hz, 15A cir-
cuit with a grounding receptacle. Do not use an 
adapter with this product. 
Extension Cords 
Use only an extension cord with an undamaged, 
3-prong plug.
For 25 to 50 ft (7.6 to 15.2 m) cords, use 3-wire, 14 
AWG (1.5 mm
2
) minimum.
For up to 100 ft. (30.48 m) cord, use 3-wire, 12 AWG 
(2.5 mm
2
) minimum.
Additional Required Equipment
Auxiliary Air Compressor
Minimum Requirements: 3.5 CFM @ 40 psi or 2.5 CFM 
@ 90 psi (maximum 100 psi)
3/8 x 25 ft minimum airline rated @ 120 psi/min
Alternate Power - Generator Requirements
3500 W (3.5 kW) minimum
ti9165a
ti8371a
ti8528a