Graco Inc. ti8370a User Manual

Page of 16
Mixing Material
9
Mixing Material
Dry Mix - 40 lb (18 kg) bag.
1.
Slowly add one 40 lb. (18 kg) bag of texture material 
to 5-6 gallons (18.9-22.7 liters) of clean water as 
instructed on the bag instructions. 
2.
Agitate to mix, using a half-inch, variable speed drill 
with mixing paddle, to a smooth, lump-free 
consistency.
3.
Allow ceiling texture to set for at least 15 minutes. 
Then remix prior to use.
4.
After texture material is thoroughly mixed, gently set 
ball end of Material Thickness Gauge on surface of 
mixture.
5.
Observe the ball on the material. When the material 
is thin enough to spray the ball will sink completely 
into the mixture.
6.
If the ball does not sink completely into the mixture 
within 10 seconds, add more water, agitate and try 
test again.
Premix
1.
Slowly add approximately 2 to 4 qts (1.9 to 3.8 liters) 
of water to a 5 gallon (18.9 liter) bucket of premix.
2.
Agitate to mix, using a half-inch, variable speed drill 
with a mixing paddle, to a smooth, lump-free consis-
tency.
3.
After texture material is thoroughly mixed, gently set 
ball end of Material Thickness Gauge on surface of 
mixture.
4.
Observe the ball in material. When the material is 
thin enough to spray the ball will sink completely into 
the mixture.
5.
If the ball does not sink completely into the mixture 
within 10 seconds, add more water, agitate and try 
test again.
Correct material mixture is essential. The pump 
will not operate if the mixture is too thick.
Mix the material in a separate container before 
pouring it into hopper.
Use Material Thickness Gauge to determine 
mixture is thin enough to spray.
*The Material Thickness Gauge will only 
determine if the material is thin enough to pass 
through the pump. For some applications or for 
higher speed spraying, your mixture may need to 
be thinner.
For best results do not use partial bags of 
material.
ti2496
ti2497#1
For an accurate test, be sure gauge is completely 
dry and clean every time it is used.
For an accurate test, be sure gauge is completely 
dry and clean every time it is used.
ADD WATER
READY
ti2498a
ADD WATER
READY
ti2498a